EasyManua.ls Logo

B&R Automation PC 620 - Exchanging a PCI SATA RAID Hard Disk

B&R Automation PC 620
594 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Maintenance / Servicing • Exchanging a PCI SATA RAID hard disk
Section 7
Maintenance / Servicing
535Automation PC 620 with 945GME N270 CPU board User's Manual V 1.10
6. Exchanging a PCI SATA RAID hard disk
In the example, the assumption is made that the secondary hard disk (HDD1) is defective. In
such a case, the defective hard disk can be replaced by the replacement drive SATA hard disk.
A size 10 Torx screwdriver is needed for exchanging the hard disk.
Exchange procedure
Remove the power supply to the device (Automation PC 620 / Panel PC 700).
Touch the housing or ground connection (not the power supply!) in order to discharge any
electrostatic charge from your body.
Remove the side cover.
Remove the SATA RAID insert.
Loosen the 4 appropriate mounting screws (M3x5) - see Figure 317 "Screw assignment
on the back side of the SATA RAID controller", on page 535.
On the front side, slide the hard disk down and away (image 1).
Carefully plug the new hard disk into the connector (image 2).
Figure 317: Screw assignment on the back side of the SATA RAID controller
Information:
When doing this, make sure that the hard disk is only touched on the front side, and
not on the top side.
Secondary Hard Disk
(HDD1)
Primary Hard Disk
(HDD0)

Table of Contents