Maintenance / Servicing • Exchanging a PCI SATA RAID hard disk
Section 7
Maintenance / Servicing
535Automation PC 620 with 945GME N270 CPU board User's Manual V 1.10
6. Exchanging a PCI SATA RAID hard disk
In the example, the assumption is made that the secondary hard disk (HDD1) is defective. In
such a case, the defective hard disk can be replaced by the replacement drive SATA hard disk.
A size 10 Torx screwdriver is needed for exchanging the hard disk.
Exchange procedure
• Remove the power supply to the device (Automation PC 620 / Panel PC 700).
• Touch the housing or ground connection (not the power supply!) in order to discharge any
electrostatic charge from your body.
• Remove the side cover.
• Remove the SATA RAID insert.
• Loosen the 4 appropriate mounting screws (M3x5) - see Figure 317 "Screw assignment
on the back side of the SATA RAID controller", on page 535.
• On the front side, slide the hard disk down and away (image 1).
• Carefully plug the new hard disk into the connector (image 2).
Figure 317: Screw assignment on the back side of the SATA RAID controller
Information:
When doing this, make sure that the hard disk is only touched on the front side, and
not on the top side.
Secondary Hard Disk
(HDD1)
Primary Hard Disk
(HDD0)