536
Maintenance / Servicing • Exchanging a PCI SATA RAID hard disk
Automation PC 620 with 945GME N270 CPU board User's Manual V 1.10
Re-secure the hard disk using the 4 fastening screws (M3x5) used earlier.
Reassemble device in the reverse order.
An error message is output by the RAID BIOS after starting the system "RAID1 set is
in Critical status - press any key to enter Configuration Utility".
A rebuild must be executed in the SATA RAID BIOS - for more information on this, see the
section "Rebuild mirrored set", on page 258.
Figure 318: Hard disk exchange