EasyManua.ls Logo

B&R Automation PC 620 - Network-Related Emissions

B&R Automation PC 620
594 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
390
Standards and certifications • Emission requirements (emission)
Automation PC 620 with 945GME N270 CPU board User's Manual V 1.10
3.1 Network-related emissions
Test carried out according to
EN 55011 / EN 55022
Limits according to
EN 61000-6-4
Limits according to
EN 55011 Class A
Limits according to
EN 55022 Class A
Power mains connections
150 kHz - 500 kHz
-79dB (µV)
Quasi-peak value
66 dB (µV)
Average
79 dB (µV)
Quasi-peak value
66 dB (µV)
Average
Power mains connections
500 kHz - 30 MHz
-73dB (µV)
Quasi-peak value
60 dB (µV)
Average
73 dB (µV)
Quasi-peak value
60 dB (µV)
Average
AC mains connections
150 kHz - 500 kHz
79 dB (µV)
Quasi-peak value
66 dB (µV)
Average
--
AC mains connections
500 kHz - 30 MHz
73 dB (µV)
Quasi-peak value
60 dB (µV)
Average
--
Other connections
150 kHz - 500 kHz
- - 97 - 87 dB (µV) und
53 - 43 dB (µA)
Quasi-peak value
84 - 74 dB (µV) und
40 - 30 dB (µA)
Average
Other connections
500 kHz - 30 MHz
- - 87 dB (µV) and 43 dB (µA)
Quasi-peak value
74 dB (µV) and 30 dB (µA)
Average
Test carried out according to
EN 55011 / EN 55022
Limits according to
EN 61131-2
Limits according to
47 CFR Part 15 Subpart B class
A
Power mains connections
1)
150 kHz - 500 kHz
79 dB (µV)
Quasi-peak value
66 dB (µV)
Average
-
Power mains connections
500 kHz - 30 MHz
73 dB (µV)
Quasi-peak value
60 dB (µV)
Average
-
AC mains connections
150 kHz - 500 kHz
-79dB (µV)
Quasi-peak value
66 dB (µV)
Average
AC mains connections
500 kHz - 30 MHz
-73dB (µV)
Quasi-peak value
60 dB (µV)
Average
Table 240: Test requirements - Network-related emissions for industrial areas