Maintenance / Servicing • Installing the UPS module
Section 7
Maintenance / Servicing
517Automation PC 620 with 945GME N270 CPU board User's Manual V 1.10
4.1.2 APC620, 2 PCI slot
Remove side cover (see section 5 "Mounting the side cover", on page 531).
Remove UPS module cover by removing the 2 marked Torx screws (T10).
Remove cover plate by removing the marked Torx screw (T10).
Screw in spacing bolt and spacing ring (using M5 hex socket screwdriver).
Install mounting bracket on UPS module using 2 Torx screws (T10).
Figure 280: Remove UPS module cover
Figure 281: Remove cover plate
Figure 282: Screw in spacing bolt and spacing ring
14 mm spacing bolt