238
Commissioning • Connection examples
Automation PC 620 with 945GME N270 CPU board User's Manual V 1.10
4.7.4 BIOS settings
No special BIOS settings are necessary for operation without touch.
To operate Automation Panel 900 panels with a touch screen (Extended Desktop or Dual
Display Clone), the serial interfaces COM C and COM D must be activated in BIOS (BIOS default
setting = disabled).
4.7.5 Windows graphics driver settings
"Notebook" must be defined as output device in the graphics driver.
For more information on this, see chapter 4 "Software", section 6 "Automation PC 620 with
Windows XP Professional", on page 351.
4.7.6 Windows touch screen driver settings
For more information on this, see chapter 4 "Software", section 6 "Automation PC 620 with
Windows XP Professional", on page 351.
Firmware Name Version Note
MTCX FPGA Firmware on the APC620 v 01.15 The version is read from BIOS - see the
BIOS description.
Supported starting with the APC620 /
PPC 700 Firmware upgrade (MTCX,
SDLR, SDLT) V01.10, available in the
download area of the B&R homepage.
MTCX PX32 Firmware on the APC620 v 01.55
SDLR FPGA Firmware on the AP Link SDL receiver and
transceiver
v 01.04
SDLT FPGA Firmware on the AP Link SDL transmitter v 00.02
Hardware Name Revision Note
5DLSDL.1000-00 AP Link SDL receiver Rev. D0
5DLSDL.1000-01 AP Link SDL transceiver Rev. D0
5AC600.SDL0-00 AP Link SDL transmitter Rev. B3
5PC600.SX01-00 System 1 PCI Rev. E0
5PC600.SX02-00 System 2 PCI, 1 disk drive slot, 1 AP Link slot Rev. D0
5PC600.SX02-01 System 2 PCI, 1 disk drive slot Rev. E0
5PC600.SF03-00 System 3 PCI, 1 disk drive slot, 1 AP Link slot Rev. A0
5PC600.SX05-00 System 5 PCI, 2 disk drive slots, 1 AP Link slot Rev. C0
5PC600.SX05-01 System 5 PCI, 2 disk drive slots Rev. C0
Table 146: Requirements for SDL cable with extender and automatic cable adjustment (equalizer)