EasyManua.ls Logo

B&R Automation PC 620 - One Automation Panel 900 Unit Via SDL (AP Link); Basic System Requirements; Link Modules

B&R Automation PC 620
594 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Commissioning • Connection examples
Section 3
Commissioning
235Automation PC 620 with 945GME N270 CPU board User's Manual V 1.10
4.7 One Automation Panel 900 unit via SDL (AP Link)
An Automation Panel 900 unit is connected to the optional SDL transmitter (AP Link) via an SDL
cable. USB devices can only be connected directly to the Automation Panel (without a hub).
4.7.1 Basic system requirements
The following table shows the possible combinations for the APC620 system unit with CPU
board to implement the configuration shown in the figure above. If the maximum resolution is
limited when making the combination then it is also shown in this table (e.g. for connecting a non-
B&R Automation Panel 900 device).
4.7.2 Link modules
Figure 100: Configuration - One Automation Panel 900 via SDL (AP Link)
CPU board with system unit
Restriction
Resolution
5PC600.SX01
-00
5PC600.SX02
-00
5PC600.SX02
-01
5PC600.SF03
-00
5PC600.SX05
-00
5PC600.SX05
-01
5PC600.SE00
-00 / -02
5PC600.X945-00 - - ✓✓ --Max. UXGA
Table 141: Possible combinations of system unit and CPU board
Model number Description Note
5DLSDL.1000-00 Automation Panel Link SDL receiver
Connection for SDL in, transfer of display data, touch screen, USB 1.1, matrix keys, and service data,
24 VDC (screw clamp 0TB103.9 or cage clamp 0TB103.91 sold separately).
For Automation
Panel 900
5AC600.SDL0-00 APC620 Smart Display Link transmitter
For connecting Automation Panels to an APC620 via SDL.
For Automation PC
620
Table 142: Link modules for the configuration: 1 Automation Panel 900 via SDL (optional)