168
Technical data • Individual components
Automation PC 620 with 945GME N270 CPU board User's Manual V 1.10
Positioning time (seek, typical values)
Minimum (track to track)
Average (read access)
Maximum (read access)
1 ms
12.5 ms
22 ms
Starting time (0 rpm to read access) 4 seconds (typically)
Interface ATA-6
Data transfer rate
On the medium
To/from host
Max. 450 MBit/s
Max. 100 MB/s (Ultra-DMA Mode 5)
S.M.A.R.T. Support Yes
Cache 8 MB
MTBF 750,000 hours
1)
Mechanical characteristics
Add-on mounting Fixed
Outer dimensions (without slide-in)
Width
Length
Height
70 mm
100 mm
9.5 mm
Weight 120 g
Environmental characteristics
Ambient temperature
2)
Operation - Standard / 24-hour
Bearings
Transport
-30 to +85°C
-40 to +95°C
-40 to +95°C
Relative humidity
Operation
Bearings
Transport
5 to 90%, non-condensing
5 to 95%, non-condensing
5 to 95%, non-condensing
Vibration
Operation
Bearings
5 - 500 Hz: 2 g; no non-recovered errors
5 - 500 Hz: 5 g; no non-recovered errors
Shock (pulse with a sine half-wave)
Operation
Bearings
Max. 300 g, 2 ms; no non-recovered errors
Max. 150 g, 11 ms; no non-recovered errors
Max. 800 g, 2 ms; no damage
Max. 400 g, 0.5 ms; no damage
Altitude
Operation
Bearings
- 300 to 5,000 meters
- 300 to 12,192 meters
1) With 8760 POH (Power On Hours) per year and 70°C surface temperature.
2) Temperature values for 305 meter altitude. The temperature specification must be reduced linearly by 1°C every 305 meters. The
temperature increase and decrease can be a maximum of 3°C per minute.
Features 5AC600.HDDI-06
Table 79: Technical data - add-on hard disk - 5AC600.HDDI-06 (cont.)