Technical data • Entire device
Section 2
Technical data
61Automation PC 620 with 945GME N270 CPU board User's Manual V 1.10
Electrical characteristics APC620, 3 PCI slot variant
Power supply
Rated voltage
Rated current
Starting current
Power consumption
24 VDC ±25%
5A
Typ. 10 A, max. 40 A for < 300 µs
Component-dependent, see section 2.9 "Power management APC620 system unit with 3 PCI slots"
Mechanical characteristics
Housing
4)
Item
Paint
Front cover
Galvanized plate, plastic
Light gray (similar to Pantone 427CV), dark gray (similar to Pantone 432CV)
Colored orange plastic (similar to Pantone 144CV)
Outer dimensions See "Dimensions", on page 62
Weight Approx. 4.5 kg (component-dependent)
Environmental characteristics
Ambient temperature
Operation
Bearings
Transport
Component-dependent, see the section about ambient temperature on page 75
-20 to +60°C
-20 to +60°C
Relative humidity
Operation
Bearings
Transport
Component-dependent, see section "Humidity specifications", on page 101
Component-dependent, see section "Humidity specifications", on page 101
Component-dependent, see section "Humidity specifications", on page 101
Vibration
5)
Operation (continuous)
Operation (occasional)
Bearings
Transport
2 - 9 Hz: 1.75 mm amplitude / 9 - 200 Hz: 0.5 g
2 - 9 Hz: 3.5 mm amplitude / 9 - 200 Hz: 1 g
2 - 8 Hz: 7.5 mm amplitude / 8 - 200 Hz: 2 g / 200 - 500 Hz: 4 g
2 - 8 Hz: 7.5 mm amplitude / 8 - 200 Hz: 2 g / 200 - 500 Hz: 4 g
Shock
5)
Operation
Bearings
Transport
15 g, 11 ms
30 g, 15 ms
30 g, 15 ms
Protection type IP20
Altitude
Operation max. 3000 m
6)
(component-dependent)
Electromagnetic compatibility
Emissions
Network-related emissions
Emissions
EN 61000-6-4, EN 55022 A
EN 61000-6-4, EN 55011 class A, EN 55022 class A, EN 61131-2, 47 CFR Part 15
Immunity
Electrostatic discharge (ESD)
High-frequency electromagnetic fields
High-speed transient disturbances
(Burst)
Surges
Conducted values
Magnetic fields with electrical
frequencies
Voltage dips, interruptions
Damped vibration
EN 61000-6-2, EN 61131-2, EN 55024
EN 61000-6-2, EN 61131-2, EN 55024
EN 61000-6-2, EN 61131-2, EN 55024
EN 61000-6-2, EN 61131-2, EN 55024
EN 61000-6-2, EN 61131-2, EN 55024
EN 61000-6-2, EN 61131-2, EN 55024
EN 61000-6-2, EN 61131-2, EN 55024
EN 61000-6-2, EN 61131-2, EN 55024
1) Maintenance controller extended.