R5906848 /04 DP2K SLP Series366
Code 20577: LDM 1-3 Heatsink rectifier temperature too high
For this error the same troubleshooting table can be applied to as for code 20377: LDM 1-2 Heatsink
rectifier temperature too high.
Code 20578: LDM 1-3 Heatsink rectifier temperature sensor shorted
For this error the same troubleshooting table can be applied to as for code 20378: LDM 1-2 Heatsink
rectifier temperature sensor shorted.
Code 20579: LDM 1-3 Heatsink rectifier temperature sensor open
For this error the same troubleshooting table can be applied to as for code 20379: LDM 1-2 Heatsink
rectifier temperature sensor open.
Code 20583: LDM 1-3 Heatsink drain temperature too high
For this error the same troubleshooting table can be applied to as for code 20377: LDM 1-2 Heatsink
rectifier temperature too high.
Code 20584: LDM 1-3 Heatsink drain temperature sensor shorted
For this error the same troubleshooting table can be applied to as for code 20378: LDM 1-2 Heatsink
rectifier temperature sensor shorted.
Code 20585: LDM 1-3 Heatsink drain temperature sensor open
For this error the same troubleshooting table can be applied to as for code 20379: LDM 1-2 Heatsink
rectifier temperature sensor open.
Code 20609: LDM 1-4 LLS bank 7 drain voltage too high
For this error the same troubleshooting table can be applied to as for code 20323: LDM 1-2 LLS bank 1
drain voltage too high.
Code 20613: LDM 1-4 LLS bank 8 drain voltage too high
For this error the same troubleshooting table can be applied to as for code 20323: LDM 1-2 LLS bank 1
drain voltage too high.
Code 20621: LDM 1-4 LLS bank 7 current too high
For this error the same troubleshooting table can be applied to as for code 20335: LDM 1-2 LLS bank 1
current too high.
Code 20625: LDM 1-4 LLS bank 8 current too high
For this error the same troubleshooting table can be applied to as for code 20335: LDM 1-2 LLS bank 1
current too high.
Code 20645: LDM 1-4 LLS bank 7 temperature too high
For this error the same troubleshooting table can be applied to as for code 20359: LDM 1-2 LLS bank 1
temperature too high.
Code 20646: LDM 1-4 LLS bank 7 temperature sensor shorted
For this error the same troubleshooting table can be applied to as for code 20360: LDM 1-2 LLS bank 1
temperature sensor shorted.
Code 20647: LDM 1-4 LLS bank 7 temperature sensor open
For this error the same troubleshooting table can be applied to as for code 20361: LDM 1-2 LLS bank 1
temperature sensor open.
Troubleshooting

Table of Contents

Other manuals for Barco DP2K SLP Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Barco DP2K SLP Series and is the answer not in the manual?

Barco DP2K SLP Series Specifications

General IconGeneral
BrandBarco
ModelDP2K SLP Series
CategoryProjector
LanguageEnglish

Related product manuals