R5906848 /04 DP2K SLP Series 381
24.03.2010 17:17:12.185 TPPL = 2848, APPL = 2048, TLPF = 4095, ALPF = 128
This line is entered when the auto timing on the ICP computes values that are not within valid ranges.
Where :
• TPPL = Total Pixels Per Line
• APPL = Active Pixels Per Line
• TLPF = Total Lines Per Frame
• ALPF = Active Lines Per Frame
• 512 <= APPL <= TPPL <= 8191
• 288 <= ALPF <= TLPF <= 4095
In this example ALPF = 128 which is less than the minimum of 288. When this happens, auto timing will
attempt to blank the image.
Troubleshooting