11SHUTDOWN, STORAGE
In this chapter we describe, how you decommission and store the device.
11.1 Safety instructions
h Refer to ZFundamental safety instructions– from page 11 and the information in
ZTransportation and packing– from page 23.
The shutdown of the device may only be carried out by for this qualified personnel.
DANGER
The following will occur, if you disregard this safety note:
m serious personal injury m death
The danger is: Electricity and electrical charge, which was saved. Electrical connections,
which are not in a current-free state, carry hazardous voltage levels.The modules in the de
-
vice (e. g. capacitors) also can carry hazardous charges after it was switched off!
Assure, that all electric connections are current-free and are safe against re-start.
Before working, check at the electrical connections with suitable measuring devices, that the
connections are off-circuit.
Remove the connections not until the safe isolation from supply has been checked.
The capacitors which are used in the device are 10 min. after interruption of supply voltage
discharged so far, that the connections can be demounted without danger.