11.2
11.2 Requirements to the executing personnel
The personnel, who is appointed to setting out of operation, must have the required
knowledge and instructions, which is necessary for an execution according to the rules.
Select the personnel in such a way, that the safety instructions, which are mounted to the
device and its parts as well as to the connections, are understood and applied to.
11.3 Shutdown
Execute the setting out of operation as follows:
1 put the device off-circuit and assure the device against unintentional restart.
2 check the isolation from supply of all connections (earliest 10 minutes after switching
off).
3 demount the connections and protect the connections according to the safety instruc-
tions.
4 document the shut down setting.
11.4 Demounting
The demounting assumes a completed, documented setting out of operation.
1 secure the device against falling off/out.
2 loosen all mechanical connections.
3 lift the device out of the control cabinet.
4 store the device in a suitable packing.
5 at transportation pay attention to, that the device is not damaged by wrong storage or
severe shocks, also see
ZTo be considered by transportation– on page 23.
In case you want to dispose the device, additional data is available in chapter ZDisposal–
from page 113.
CAUTION
The following may occur, if you disregard these safety notes:
m minor to medium personal injury.
In case, while installing, you lift a device with unprotected hands, fingers/palm can be cut. If
the device falls off, your feet can be cut up.
Wear safety gloves
Wear safety shoes