Warning code Warning name Warning descriptions Parameter
7 cE10 Warning: communication modbus P0862
8 oL2 Warning: motor load exceeded P1213
9 AUE Warning: auto tuning error -
10 Uc Warning: under voltage -
11 SE1 Warning: keypad copy parameter operation error -
12 SE2 Warning: keypad copy parameter save error -
13 PtC2 Warning: motor PTC temperature exceeded P1012
14 PGEr Warning: PG (encoder) loss P1077
15 FbE Warning: PID feedback P1368
16 SAvE Warning: keypad copying -
23 PE10 Warning: IO COM1 communication time out P0868
25 Lv Warning: DC BUS voltage has lower than standard
voltage
P0297
26 Aerr Warning: control board ACI (current) loss P0806
27 bb Warning: base block P1091 to P1100
33 CSdo Warning: CANopen SDO time out
34 CSfF Warning: CANopen buffer overflow
36 CbtU Warning: CANopen boot up error
50 cc01 Warning: At least one of the error counters of the
CANopen slave has reached the value 96
51 cc03 Warning : The SYNC-message is not received
within the configured time
52 UbCd Warning: communication error USB card P0868
53 cPt2 Warning: CAN error