B
B.3.2 Output chokes recommended values
230V, 50/60Hz, 1-phase
460V, 50/60Hz, 3-phase
Device kW Fundamental
A
Max. continuous
A
Inductance (mH)
3 % impedance 5 % impedance
BM1211 0.2 4 4 9 12
BM1212 0.4 6 6 6.5 9
BM1213 0.75 8 12 3 5
BM1224 1.5 8 12 1.5 3
BM1225 2.2 12 18 1.25 2.5
Device kW Fundamental
amps
Max. continuous
amps
Inductance (mH)
3 % impedance 5 % impedance
BM1412 0.4 2 3 20 32
BM1413 0.75 4 6 9 12
BM1414 1.5 4 6 6.5 9
BM1425 2.2 8 12 5 7.5
BM1426 3.7 12 18 2.5 4.2
BM1437 5.5 18 27 1.5 2.5
BM1438 7.5 18 27 1.5 2.5
BM1439 11 25 37.5 1.2 2