Interface assignment
Manual b maXX
®
BM1000
Document No. 5.07003.04 Baumüller Nürnberg GmbH
150
of 174
E.1
E.1 Interface assignment
The interface is used to realize the communication within a CANopen ring or to communicate
with the b
maXX
®
BM1000 via Modbus.
In addition the interface can be used as a power supply for external devices, e.g. communication
modules.
E.2 Terminating plug for CANopen
The b maXX
®
BM1000 must be equipped with a termination plug BM4-CAN-T01 (according
CIA Standard 120 Ω, 0.25 W) if the device is the last participant within the CANopen network,
see
ZAccessories CANopen– on page 136.
E.3 Connection cables
For available connection cables refer to ZAccessories CANopen– on page 136.
Pin assignment Pin no. CANopen Modbus (RS485)
Female connector 8-pin 1 CAN high
2 CAN low
3 CAN GND
4 SG -
5 SG +
6 reserved reserved
7 CAN GND
8 reserved reserved