272
Operating Instructions ACU
12/16
Frequency ramps
No.
Description
Unit
Setting range
Chapter
420
Acceleration (Clockwise)
Hz/s
0.00 ... 9999.99
15.7
421
Deceleration (Clockwise)
Hz/s
0.01 ... 9999.99
15.7
422
Acceleration Anticlockwise
Hz/s
-0.01 ... 9999.99
15.7
423
Deceleration anticlockwise
Hz/s
-0.01 ... 9999.99
15.7
424
Emergency stop clockwise
Hz/s
0.01 ... 9999.99
15.7
425
Emergency stop anti-clockwise
Hz/s
0.01 ... 9999.99
15.7
426
Maximum leading
Hz
0.01 ... 599.00
15.7
430
Ramp rise time clockwise
ms
0 ... 65000
15.7
431
Ramp fall time clockwise
ms
0 ... 65000
15.7
432
Ramp Rise Time Anticlockwise
ms
0 ... 65000
15.7
433
Ramp Fall Time Anticlockwise
ms
0 ... 65000
15.7
Traverse function
435
Operation mode
-
Selection
19.8
436
Acceleration Time
s
0.01 … 320.00
19.8
437
Deceleration Time
s
0.01 … 320.00
19.8
438
Traverse Amplitude
%
0.01 … 50.00
19.8
439
Proportional Step
%
0.01 … 50.00
19.8
Technology controller
440
Operation mode
-
Selection
18.3
441
Fixed frequency
Hz
-599.00 ... 599.00
18.3
442
max. P component
Hz
0.01 ... 599.00
18.3
443
Hysteresis
%
0.01 ... 100.00
18.3
444
Amplification
-
-15.00 ... 15.00
18.3
445
Integral Time
ms
0 ... 32767
18.3
446
Ind. volume flow control factor
-
0.10 ... 2.00
18.3
Blocking frequencies
447
1st Blocking Frequency
Hz
0.00 ... 599.00
15.9
448
2nd Blocking Frequency
Hz
0.00 ... 599.00
15.9
449
Frequency hysteresis
Hz
0.00 ... 100.00
15.9
Multifunction input 1
450
Tolerance Band
%
0.00 ... 25.00
16.1.1.3
451
Filter time constant
ms
Selection
16.1.1.4
452
Operation mode
-
Selection
16.1
453
Error/Warning Behavior
-
Selection
16.1.1.5
454
Point X1
%
0.00 ... 100.00
16.1.1.1
455
Point Y1
%
-100.00 ... 100.00
16.1.1.1
456
Point X2
%
0.00 ... 100.00
16.1.1.1
457
Point Y2
%
-100.00 ... 100.00
16.1.1.1
Positioning
458
Operation mode
-
Selection
13.6
459
Signal source
-
Selection
13.6.1
460
Positioning distance
U
0.000 ... 1 10
6
13.6.1
461
Signal correction
ms
-327.68 ... 327.67
13.6.1
462
Load correction
-
-32768 ... 32767
13.6.1
463
Activity after positioning
-
Selection
13.6.1
464
Time to wait
ms
0 ... 3.6 10
6
13.6.1

Table of Contents

Other manuals for BONFIGLIOLI active cube 201

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the BONFIGLIOLI active cube 201 and is the answer not in the manual?

BONFIGLIOLI active cube 201 Specifications

General IconGeneral
BrandBONFIGLIOLI
Modelactive cube 201
CategoryDC Drives
LanguageEnglish

Related product manuals