Indications
Element Description
These indicators show the reduction in dB that is applied to the audio signal by the compressor (COMP)
or limiter. Level reduction is indicated as vertical yellow bar graph.
The margin level indicates the distance between signal level and the set absolute level. The displayed
margin relates to the highest actual signal level reading since the last reset of the indicator. The LED
changes from green to red as soon as the signal level reaches or exceeds the set absolute level (Digital
Clip / Limiter Threshold). A click with the right mouse button onto the margin level followed by click onto
Reset re-sets indication.
Editing Compressor / Limiter Parameters by Dragging the Mouse in the Graphics Display
Active compressors or limiters (bypass button is not engaged) are indicated by a white dot in the graphics display
representing its function. A click with the left mouse button onto this dot and keeping the mouse button pressed down
lets you set the threshold for the corresponding compressor or limiter by vertically dragging the mouse. A click with the
right mouse button onto the white dot of a compressor and keeping the mouse button pressed down lets you edit the
ratio of compression.
A compressor’s / limiter’s title lights in color as soon as the mouse cursor is positioned on top of the corresponding
white dot to provide improved overview and handling.
IRIS-Net
REMOTE AMPLIFIER | en 137
Bosch Security Systems B.V. User Manual 2017.05 | 3.20 | F.01U.119.956