Element
Description
Power Limit Enter the maximum power consumption of the loudspeaker cabinet used (refer
to datasheet) in this field.
Nominal Impedance Enter the impedance of the loudspeaker cabinet used (refer to datasheet) in
this field.
Amp Type Select the used type of power amplifier in this dropdown menu.
Limiter Threshold This field shows the result of the calculation in dBu. The value is also shown in
dBu.
Clicking onto this button closes the Limiter Threshold Calculator.
Using the Event Scheduler
The Event Scheduler is divided into three windows. On the Events tab you can create and edit nonrecurring as well as
periodically recurring events. The Day Programs tab allows creating lists of daily recurring events. The Holiday tab lets
you specify periods – like for example school holidays – during which an alternative Day Program shall be used instead
of the standard Day Program.
Events
This window allows creating nonrecurring as well as periodically recurring events. If an event occurs, a macro is being
executed.
IRIS-Net IRIS-Net | en 49