/SYNC R / W ON, OFF Lets you select whether the control
outputs can be synchronized using a
special CAN-command.
/PRM /.. Parameters and values for functions
mentioned above
/OFF ... (same as above but for switching off a
control output)
/OUT2 ... (same as above but for the control
output 2)
/MEMFLAG /SET R / W NONE,
1...16
List of currently set Memo flags
/CLR R / W NONE,
1...16
List of currently reset Memo flags
Commands for Receive and Transmit job
codes
/JOB /RX1 /ID R / W 0...FFFF Number (ID) in hex for job code to be
received. Each power amp can receive
and interpret up to 5 job codes.
/FNCT R / W NOTHING,
POWER,
ABS, REL,
TOG- GLE,
PRESET,
MONI,
MEMFLAG,
MEAS,
TEST- GEN
Function when receiving a job code.
For further details please refer to table
"Job Codes - Receive Functions" on this
page.
/PRM /... Parameters and values for functions
mentioned above
...
/RX5 ... (same as above but for receiving Job
Codes 2 to 5)
/TX1 /ID R / W 0...FFFF Number (ID) for job code to be
transmitted. Each power amp can
transmit up to 5 job codes.
/TIME R / W 0...10.0 [s] Delay / debounce time for programmed
condition
IRIS-Net REMOTE AMPLIFIER | en 224
Bosch Security Systems B.V. User Manual 2017.05 | 3.20 | F.01U.119.956