100 ms 10...1000 ms RELEASE defines how fast the output signal returns to its
normal level once it drops below the threshold.
BYPASS activates (not engaged) or deactivates (engaged) the
Limiter, which allows for quick A / B comparison between the
limited and unlimited audio signal.
RMS-COMPRESSOR
The compressor reduces the dynamic range of audio signals. Once the signal exceeds a certain threshold,
the signal gets compressed, i.e. major input level changes result in minor output level changes. Narrowing the dynamic
range often allows for easier recording or mixing the audio signal.
Compressors with effective value analysis in monaural (1 input and 1 output) and stereo quality (2 inputs and 2
outputs) are provided. A side channel input allows feeding the compressor with an external control signal, which, for
example, can also be the input signal processed by an equalizer. As a result the compressor reacts to specific
frequency bands more than to others. However, using a totally different trigger signal lets you achieve various special
effects.
Element
Default Range Description
The attenuation (gain reduction) indicator signals
the degree of level reduction in dB. A red bar that
increases from right to left indicates the degree of
gain reduction.
IRIS-Net DIGITAL MATRIX | en 450
Bosch Security Systems B.V. User Manual 2017.05 | 3.20 | F.01U.119.956