EasyManua.ls Logo

Bosch IRIS-Net - Page 457

Bosch IRIS-Net
994 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Commands for CAN-BUS communication
Read
Write
Values
Description
/PARAM /CAN /MONITOR /VALUE R error! (unknown
channel),
INPUT_A RCM: X,
INPUT_B RCM:
X,OUTPUT_A
RCM:X,
OUTPUT_B RCM:
X
Input or output channel of
amplifier (with CAN address
X) currently selected for
monitor bus
/SCANSTATE /VALUE R SCAN_FAILED,
SCAN_READY
State of CAN-BUS after scan
/FUNCTIONS /CAN_RESET exec none Reset of CAN-BUS
/CAN_SCAN exec none Scan CAN-BUS for new devices
/SET_BAUD_
ALL
exec 10, 20, 63, 125,
250, 500
Set new Baud rate of the
device and all devices
connected to the CAN-BUS
/SET_
MONITOR
exec input_a, input_b,
output_a,
output_b; 1-250
Selects Monitor Bus of a
remote amplifier
Commands for system queries
Read
Write
Values
Description
/PARAM /LOCAL /
CHASSISTEMP
/VALUE R Device temperature in degree Celsius
/FANSPEED /VALUE R / W 0, 1, 2, 3 Fan speed (0 = off, 1 = slow, 2 = mid,
3= fast)
/GPIANALOG /
IDX1...IDX4
R 0, 1 State of GPI using analog circuit
/GPIDIGITAL /
IDX1...IDX4
R 0, 1 State of GPI using digital circuit
/GPO /
IDX1...IDX3
R / W 0, 1 State of GPO (0 = open, 1 = closed)
/
REMOTEFAUL
T
/
IDX1...IDX1
00
R 0, 1 State of remote device (0 = OK, 1 =
does not answer)
/
CONDRESULT
/
IDX1...IDX1
00
R 0, 1 State of condition (0 = false, 1 = true)
IRIS-Net DIGITAL MATRIX | en 457
Bosch Security Systems B.V. User Manual 2017.05 | 3.20 | F.01U.119.956