Commands for Ducker
Read Write
Values
Description
/
PARA
M
/DSP /
DUCKE
R_x
/ATTACK /
VALU
E
R / W 5...1000 Attack time in ms
/BYPASS /
VALU
E
R / W 0, 1 0 = Bypass not activated, 1 = Bypass
activated
/
DUCKINGLE
VEL
/
VALU
E
R / W -100...-6 Ducking level in dB
/
GAINREDU
CTION
/
VALU
E
R Gain reduction as full scale value (32
bit) Transform given value into dB by:
20 log (0x7FFFFF/ value)
/HOLD /
VALU
E
R / W 10...200
0
Hold time in ms
/LINEMUTE /
VALU
E
R / W 0, 1 Mute of LINE input (0 = not muted, 1
= muted)
/MICMUTE /
VALU
E
R / W 0, 1 Mute of MIC input (0 = not muted, 1 =
muted)
/MIXLINE /
VALU
E
R / W -30...0 Gain of LINE input
/MIXMIC /
VALU
E
R / W -30...0 Gain of MIC input
/RELEASE /
VALU
E
R / W 5...1000 Release time in ms
/
THRESHOL
D
/
VALU
E
R / W -15...21 Threshold in dB
IRIS-Net DIGITAL MATRIX | en 469