Commands for FIR Filter
Read Write
Values
Description
/
PARA
M
/DSP /FIR_x /BYPASS /VALUE R / W 0, 1 0 = Bypass not activated, 1 =
Bypass activated
/FS /VALUE R 20...2000
0
Sampling frequency of filter
/
HIPASS.FREQ
/VALUE R 20...2000
0
Frequency of high pass
/
LOPASS.FRE
Q
/VALUE R 20...2000
0
Frequency of low pass
/MAXORDER /VALUE R Maximum order of filter
/ORDER /VALUE R Order of loaded filter
/SLOPE /VALUE R 21...100 Slope of filter (in dB)
/TYPE /VALUE R 0 = Low
Pass, 1 =
High
Pass, 2 =
Band
Pass
Type of filter
Commands for DSP Presets
Read Write
Values
Description
/
PARA
M
/DSP /
FUNCTIO
NS
/DELETE_PRESET exec 1...60 Delete preset
/LOAD_PRESET exec 1...60 Load preset
/
PRESET_INFO_READ
exec 1...60 Read description of preset
/PRESET_SET_DESC W 1...60
descrip-
tion
Set description of preset (max.
32 characters)
/PRESET_SET_PROP W 1...60
MUTE/
NOMUTE
Set mute/unmute of preset
during load