/XOVER.MUTE /VALUE R / W 0, 1 0 = not muted, 1 =
muted
/
XOVER.POLA
RITY
/VALUE R / W 0, 1 0 = normal, 1 =
inverted
/XOVER.LINK /VALUE R / W 2, 4, 6, 8 ,
10,
12, 14, 16
Links the LOPASS and
HIPASS of adjacent
ways. Link-Numbers
are used for linking
two ways, for linking
more than two ways
the sum of the cor-
responding Link-
Numbers is used.
/
XOVER.LOPA
SS.FREQ
/VALUE R / W 20...2000
0
Frequency of lopass.
/
XOVER.LOPA
SS.TYPE
/VALUE R / W 0...17 Type of lopass.
0 = Off, 1 = 6dB-
Butter-
worth, 2 = 12dB/Q0.5,
3
= 12dB/Q0.6, 4 =
12dB/ Q0.7, 5 = 12dB/
Q0.8, 6
= 12dB/Q1.0, 7 =
12dB/ Q1.2, 8 = 12dB/
Q1.5, 9
= 12dB/Q2.0, 10 =
12dB-Bessel, 11 =
12dB-Butterworth, 12
=
12dB-Linkwitz, 13 =
18dB-Bessel, 14 =
18dB-Butterworth, 15
=
24dB-Bessel, 16 =
24dB-Butterworth, 17
= 24dB-Linkwitz