Commands for Tone Control
Read
Write
Values
Description
/PARAM /DS
P
/TONE
CONTROL_x
/GAIN /
IDX1...IDX3
R / W -18...1
2
Gain of band
Commands for Tone generator
Read
Write
Values
Description
/
PARA
M
/DS
P
/TONE
GENERATOR_x
/ENABLE /VALUE R / W 0, 1 0 = off, 1 = on
/FREQ /VALUE R / W 20...2000
0
Constant frequency (for
SINE mode)
/GAIN /VALUE R / W -60...0 Gain of generated tone
/SWEEPREP /VALUE R / W 0, 1 Selection of a single or
periodic sweep (0 = one
time, 1 = periodic)
/SWEEPSTART /VALUE R / W 20...2000
0
Lower (or upper)
frequency of sweep
/SWEEPSTOP /VALUE R / W 20...2000
0
Upper (or lower)
frequency of sweep
/SWEEPTIME /VALUE R / W 5...120 Time of sweep in seconds
/TYPE /VALUE R / W 0, 1 Selection of SINE or
SWEEP mode (0 = SINE, 1
= SWEEP)
Commands for Crossover
Rea
d
Writ
e
Values
Description
/PARAM /DS
P
/
XOVER
_x
/GAIN /
IDX1...IDXn
R /
W
-30...6 Gain of crossover ways. Ways are
numbered top-down.
(e.g. IDX1 = HIGH, IDX2 = MID, IDX3 =
LOW)
/
HIPASS.FR
EQ
/
IDX1...IDXn
R /
W
20...2000
0
Frequency of hipass. Ways are
numbered top-down.
(e.g. IDX1 = HIGH, IDX2 = MID, IDX3 =
LOW)
IRIS-Net DIGITAL MATRIX | en 481