53-1002177-19 Hardware Installation Guide
Brocade DCX 8510-4 Backbone Hardware Installation Guide
Complete the following steps to download the firmware from an FTP server.
1. Log in to the standby CP blade as admin. If you need to know the IP address of the standby blade, run ipaddrshow.
You should remain logged in to the active CP blade in order to monitor it.
2. Run firmwareDownload -s to download the firmware to the standby CP blade. The -s option also disables the
autoreboot, so you will have to manually issue a reboot after the download finishes to initiate firmwarecommit. Enter
all requested information (use default values).
3. When the download process finishes, run firmwareDownloadStatus to verify that the firmware has been updated.
The command displays a running account of the progress of the firmwareDownload command (if it is still running)
until the command has completed. The final message is similar to the following and will appear with a date and time
stamp.
NOTE
The slot number for the CP blade is different for a chassis with slots for four port blades and a chassis with
slots for eight port blades. The slot number in the following example is for a chassis with slots for four port
blades.
Slot 4 (CP0, active): Firmwaredownload command has completed successfully. Use firmwareshow to verify the
firmware versions.
4. On the standby CP blade (the blade for which you just changed the firmware level), run reboot. The reboot of the
standby CP will initiate a firmwarecommit to the secondary partition and log you out.
DCX_124:admin> reboot
Broadcast message from root (ttyS0) Fri Jun 18 14:49:45 2010...
The system is going down for reboot NOW !!
INIT: Switching to runlevel: 6
INIT: Sending processes the TERM signal DCX_124:admin> HAMu Heartbeat down, stop FSS
Unmounting all f##exiting due to signal: 9, pending signals: 0x20000, 0x0
ilesystems.
Please stand by while rebooting the system...
Restarting system.
The system is coming up, please wait...
.
.
.
Fri Jun 18 14:53:13 2010: Doing firmwarecommit now.
Please wait ...
Fri Jun 18 14:55:27 2010: Firmware commit completes successfully.
Validating the filesystem ...
Fri Jun 18 22:36:05 2010: Doing firmwarecommit now.
Please wait ...
Fri Jun 18 22:36:48 2010: Firmware commit completes successfully.
2010/06/18-14:56:50, [SULB-1004], 908, SLOT 7 | CHASSIS, INFO, Brocade_DCX, Firmwarecommit has completed.
2010/06/18-14:56:50, [SULB-1036], 909, SLOT 7 | CHASSIS, INFO, Brocade_DCX, The new Version: Fabric OS
[version]
2010/06/18-14:56:50, [SULB-1002], 910, SLOT 7 | CHASSIS, INFO, Brocade_DCX, Firmwaredownload command has
completed successfully.
53-1002177-19
114
Broadcom

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Broadcom Brocade DCX 8510-4 Backbone and is the answer not in the manual?

Broadcom Brocade DCX 8510-4 Backbone Specifications

General IconGeneral
BrandBroadcom
ModelBrocade DCX 8510-4 Backbone
CategoryNetwork Hardware
LanguageEnglish