53-1002177-19 Hardware Installation Guide
Brocade DCX 8510-4 Backbone Hardware Installation Guide
8. Log back on to the standby CP blade and enter firmwareDownloadStatus on the standby CP blade to validate a
successful commit. This may take 10 minutes.
9. If you are upgrading through several levels of the Fabric OS, repeat step 5 through step 8 as often as necessary
based on the path outlined in the preceding table. Otherwise, proceed to step 10.
10. Log out of the standby CP blade and log on to the active CP blade.
11. Proceed to the procedures to "Completing the replacement."
Completing the replacement
Complete the following steps to complete the CP blade replacement procedure.
1. Enter haEnable to re-enable HA on the active CP blade.
NOTE
The haEnable command will cause the standby CP blade to reboot. Wait until POST completes before
moving to the next step. POST is complete when the Status LED on the CP blade returns to a steady green
state.
2. Enter haShow and verify that the command output includes "HA Enabled, Heartbeat Up". If it is not yet enabled, re-
enter the command until you have verified that redundancy is achieved.
NOTE
The haEnable command will cause the standby CP blade to reboot. The slot number for the CP blade is
different for a chassis with slots for four port blades and a chassis with slots for eight port blades. The slot
number in the following example is for a chassis with slots for eight port blades.
DCX_124:admin> hashow
Local CP (Slot 7, CP1) : Active
Remote CP (Slot 6, CP0) : Standby, Healthy
HA Enabled, Heartbeat Up, HA State Synchronized
3. Enter firmwareShow to verify that the firmware version has been updated and that the versions are the same on the
two CP blades.
NOTE
The slot number for the CP blade is different for a chassis with slots for four port blades and a chassis with
slots for eight port blades. The slot number in the following example is for a chassis with slots for four port
blades.
DCX_8510:admin> firmwareshow
Slot Name Appl Primary/Secondary Versions Status
-----------------------------------------------------------
2 FX8-24 FOS v7.4.0
v7.4.0
4 CP0 FOS v7.4.0 STANDBY
v7.4.0
5 CP1 FOS v7.4.0 ACTIVE *
v7.4.0
7 FX8-24 FOS v7.4.0
v7.4.0
53-1002177-19
119
Broadcom

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Broadcom Brocade DCX 8510-4 Backbone and is the answer not in the manual?

Broadcom Brocade DCX 8510-4 Backbone Specifications

General IconGeneral
BrandBroadcom
ModelBrocade DCX 8510-4 Backbone
CategoryNetwork Hardware
LanguageEnglish