53-1002177-19 Hardware Installation Guide
Brocade DCX 8510-4 Backbone Hardware Installation Guide
the directions under Downloading firmware from an FTP server or Downloading firmware from a USB device
carefully.
NOTE
If the new CP blade does not have the same firmware as the active CP blade, the new blade must be upgraded
to the same firmware version. You can determine the firmware version on the replacement blade and perform a
firmware upgrade if necessary after inserting the blade in the chassis, but you must disable high availability (HA)
before inserting the new blade. If the new CP blade is severely down-level, a very specific procedure must be
followed to bring the blade up to the correct firmware version.
Time and items required
The replacement procedure for the CP blade takes approximately 30 minutes. The following items are required for the CP
blade replacement:
•
Electrostatic discharge (ESD) grounding strap
•
Workstation computer
•
Serial cable
•
IP address of an FTP server for backing up the device configuration
•
#2 Phillips screwdriver
•
Replacement CP blade
Faulty CP blade indicators
Confirm that you need to replace the CP blade. The following events may indicate that a CP blade is faulty:
•
The status LED on the CP blade is lit steady amber, or the power LED is not lit.
•
The CP blade does not respond to Telnet commands, or the serial console is not available.
•
The slotShow command does not show that the CP blade is enabled.
•
The haShow command indicates an error.
•
The clock is inaccurate, or the CP blade does not boot up or shut down normally.
•
Any of the following messages display in the error log:
–
"Slot unknown" message relating to a CP slot
–
CP blade errors or I2C timeouts
–
FRU: FRU_FAULTY messages for a CP blade
–
Configuration loader messages or "Sys PCI config" messages
–
Generic system driver messages ("FABSYS")
–
Platform system driver messages ("Platform")
–
EM messages that indicate a problem with a CP blade
–
Function fail messages for the CP master
For more information about error messages, refer to the Brocade Fabric OS Message Reference.
Recording critical device information
Back up the backbone configuration before you replace a CP blade. Refer to the Brocade Fabric OS Administration Guide
for backup information.