REFERENCE INFORMATION
SERVICE SPECIFICATIONS AA MODELS
11
1
SERVICE SPECIFICATIONS AA MODELS
40 – 60 HP E-TEC Models
ELECTRICAL
Minimum Battery
Requirements
640 CCA (800 MCA) or 800 CCA (1000 MCA) below 32° F (0° C)
Alternator
25-Amp fully regulated. Refer to Installation and Predelivery Guide for multiple battery
applications.
Tachometer Setting 6 pulse (12 pole)
Engine Fuse P/N 967545 – 10 A
COOLING
Thermostat 143°F (62°C)
Maximum Temperature 212°F (100°C)
Water pressure 12 to 14 psi @ 5000 RPM
IGNITION
Type Capacitor Discharge
Firing Order 1-2
Ignition Timing EMM Controlled
RPM Limit in Gear 6250
RPM Limit in Neutral 1800
Crankshaft Position Sensor Air
Gap
Fixed
Spark Plug
Refer to Emission Control Information Label
Champion
QC10WEP @ 0.028 ± 0.003 in. (0.71 mm)
GEARCASE
Gear Ratio 12:32 (.375)
Lubricant
HPF XR Gearcase Lube
HPF Pro in high performance or commercial applications
Capacity 22 fl. oz. (650 ml)
Shift Rod Height 20 in. (L) Models: 21.38 (543 mm) ± one-half turn
Shift Cable Stroke 1.125 to 1.330 in. (28.6 to 33.8 mm) measured between NEUTRAL and FORWARD
POWER TRIM/TILT
Lubrication Evinrude/Johnson Biodegradable TNT Fluid
Fluid Capacity 15.2 fl. oz. (450 ml)
Trim Range 0° to 15°
Tilt Range 16° to 65°

Table of Contents