ROUTINE SERVICE
COOLING SYSTEM
Tachometer Pulse Setting
(SystemCheck)
Confirm accuracy of tachometer reading.
Adjust dial on back of tachometer to required
setting (the outboard should not be running).
Water Pump Overboard Indicator
A steady stream of water should flow from the
overboard indicator.
Operating Temperature
An outboard run at idle speed should achieve a
temperature based on the engine’s thermostatic
control. In general, the powerhead temperature
should reach at least 104°F (40°C) after five min-
utes of idling. Check that the powerhead reaches
idle temperature. Refer to SERVICE SPECIFICA-
TIONS AB MODELS on p. 12.
Idle Speed
Make sure the outboard idles within the specified
idle RPM range. If the outboard is run on a flush-
ing device, the idle speed and quality may not be
representative of actual in water use.
COOLING SYSTEM
Regularly inspect cooling system components for
corrosion, damage, leaks, or restrictions:
water intake screens
water pump
all internal water passages
thermostats
all external water hoses and fittings
vapor separator cooling passages and fittings
EMM cooling passages and fittings
overboard water pressure indicator.
Water Intake Screens
Inspect condition of water intake screens. Clean
or replace as needed.
Confirm function of overboard water pressure indi-
cator.
Outboard Model Tachometer Setting
40–90 HP 6 Pulse or 12 Pole
1. Water pump overboard indicator 008469
1
1. Water intake screen
2. Overboard indicator
001212
008470
1
2