ROUTINE SERVICE
OETIKER CLAMP SERVICING
Clamp Installation
A constant stress should be applied to close the
ear clamps. This method ensures a positive stress
on the hose and does not result in excessive com-
pression or expansion of the band material.
IMPORTANT: Use only Oetiker recommended
tools to close Oetiker stepless clamps.
Oetiker pincers are available in the Evinrude/
Johnson Genuine Parts and Accessories Catalog.
Position correct size clamp over hose.
Install hose on fitting.
Close clamp ear fully with Oetiker pincers (pli-
ers).
Clamp Removal
Method 1: Position Oetiker pincers across clamp
ear and cut clamp.
Method 2: Lift end of stepless clamp with screw-
driver.
Method 3: Use Oetiker pincers (pliers) to grip
clamp. Pull clamp off of connection and discard.
DP0886
1. Open clamp
2. Closed clamp
000092
000108
000090
000091