353
TRIM AND TILT
TRIM AND TILT SERVICE
13
Slowly remove the manual release valve. There
may be pressure behind the valve—wear safety
glasses.
Inspect the manual release valve. Discard the O-
rings on the housing.
Oil O-rings and install them on the manual release
valve. Oil and install the manual release valve.
Tighten the valve to a torque of 45 to 55 in. lbs. (5
to 6 N·m).
Install new retaining ring in groove.
40 - 60 HP Models 002529
75 - 90 HP Models 004285
007108
40 - 60 HP Models 002529
75 - 90 HP Models 004285
1. Retaining ring 002534