IO-Link - Design
14.2 Quickstart for Type 8681 IO-Link
Network layout:
IO-Link devices are connected with standard commercial IO-Link masters and can easily be integrated into
allcommonlyusedeldbusandautomationsystems.
The network is structured similarly to the diagram in “Fig.34”.
3-pin or 5-pin unshielded standard cables 20 m in length between the IO-Link device and IO-Link master
aresucientforconnectingIO-LinkdeviceswithIO-Linkmasters.
TheIO-LinkcontrolheadsareeitherequippedwithM12connectors(variantwithmulti-poleplug)orcanbe
wiredthemselves(variantwithcablegland).Fordetailssee“14.5”.
Conguration:
Thenetworkisconguredbythehigher-levelcontroller.
To ensure clear communication, IO-Link devices should not be parametrised simultaneously by the higher-
levelcontroller(PLC)viatheIO-LinkmasterandwiththeBürkertCommunicator(viatheserviceinterface).
See details in “14.4”
Software download / rmware updates:
Downloadtherequiredsoftwareles/IODDandtheobjectdescriptionfrom:
www.burkert.com/searchterm:8681/Downloads/Software/“InitiationFilesEDSIODD”(ziple).
See details in chapter “14.6”onpage84.
14.3 Technical data / specication
IO-Link specication: Version 1.1.2
Port class: A: sharedpowersupply(Power1)forsupplyofthesystemand
actuators(solenoidvalves)or
B: Separatepowersupplyforthesystem(Power1)andfor
theactuators/solenoidvalves(Power2)
Power supply: Port class A: viaIO-Linkport(M12x1,4-poleA-coded);
Port class B: viaIO-Linkport(M12x1,5-pole,A-coded),
for details see chapter “14.5.5” and “Fig.37”onpage83)
Operation mode:
 IO-Linkoperationmode(SIOoperationmodeisnotsupported)
IODD le: Download from: www.burkert.com / Type 8681 / Downloads /
Software(“InitiationFiles”-ziple)
VendorID: 0x78, 120
DeviceID: SeerelevantIODDle(portclassAorB)
Transmission speed COM3(230.4kbit/s)
M sequence type in Operate Mode: TYPE_2_V
Min. cycle time: 2 ms
Data storage: yes
Max. line length: 20 m between IO-Link master and IO-Link device