15.14.2 Setting the büS/CANopen address (Node ID)
NodeID =[DIP1·2
0
+DIP2·2
1
+DIP3·2
2
+DIP4·2
3
+DIP5·2
4
+DIP6·2
5
]
withDIPx=o=0andDIPx=on=1
Table of settings of the büS/CANopen address:
Node ID DIP1 DIP2 DIP3 DIP4 DIP5 DIP6 Node ID DIP1 DIP2 DIP3 DIP4 DIP5 DIP6
0 *) o o o o o o 32 o o o o o on
1 on o o o o o 33 on o o o o on
2 o on o o o o 34 o on o o o on
3 on on o o o o 35 on on o o o on
4 o o on o o o 36 o o on o o on
5 on o on o o o 37 on o on o o on
6 o on on o o o 38 o on on o o on
7 on on on o o o 39 on on on o o on
8 o o o on o o 40
o o o on o on
9 on o o on o o 41 on o o on o on
10 o on o on o o 42 o on o on o on
11 on on o on o o 43 on on o on o on
12 o o on on o o 44 o o on on o on
13 on o on on o o 45 on o on on o on
14 o on on on o o 46 o on on on o on
15 on on on on o o 47 on on on on o on
16 o o o o on o 48 o o o o on on
17 on o o o on o 49 on o o o on on
18 o
on o o on o 50 o on o o on on
19 on on o o on o 51 on on o o on on
20 o o on o on o 52 o o on o on on
21 on o on o on o 53 on o on o on on
22 o on on o on o 54 o on on o on on
23 on on on o on o 55 on on on o on on
24 o o o on on o 56 o o o on on on
25 on o o on on o 57 on o o on on on
26 o on o on on o 58 o on o on on on
27 on on o on on o 59 on on
o on on on
28 o o on on on o 60 o o on on on on
29 on o on on on o 61 on o on on on on
30 o on on on on o 62 o on on on on on
31 on on on on on o 63 on on on on on on
To apply any changes to settings, restart the device!
(SeeNOTE box 1 forrestartingonnextpage)
*) This is the factory setting. (ForexplanationsseeNOTE box 2 onnextpage)
For easy start-up when using a precongured gateway, a node ID between 1 and 63 should be set on the
deviceusingtheDIPswitches.Otherwise,adevicecongurationonsiteviaBürkertCommunicatorisrequired