THS – FI022GB2K8v3 --- V - MAINTENANCE
39
Observe current regulations regarding electrical and personal safety for both the operator and the installer
when installing the device.
Connect the apparatus to the mains power supply only after first carrying out all the other connections needed
for complete installation.
ALM card electrical connections
Table II-D ALM card connections
Connector
Pin Label Input/
Output
Type Range /Max. value Function
ALM-J1 - - - - -
Reserved
ALM-J2 - - - - -
Reserved
ALM-J3 7-8 - Input N.C. contact -
Emergency button
ALM-J4 1
2
3
4
5
6
NC
ISO GND
RX-
RX+
TX+
TX-
-
-
Input
Input
Output
Output
NC
ground
RX-
RX+
TX+
TX-
RS 485 serial connection
(see next table)
N.B.. the ground contact is insulated from the power
supply unit ground, and is provided for connection of
RS485 cable shielding (if required)
ALM-J5 1
2
3
4
5
-V
-V
TXD
RXD
+VB
Output
Output
Output
Input
Output
-V
-V
TXD
RXD
+VB
0V
0V
-
-
20-26Vcc, 0.15A
Bar-code reader
ALM-J6 2
3
5
6
-
-
-
-
Input
Output
-
Input
RXD
TXD
ground
DTR
-
-
-
-
RS 232 serial connection
(see next table)
ALM-J7 - - - - -
reserved
ALM-J8 - - - - -
reserved
ALM-J9 - - - - -
reserved
ALM-J10 1
2
3
+Vin
lid full
-V
-
Input
-
+V
N.O. contact*
ground
20-26Vcc, **
0V... +Vin
-
+V (high logic level/sensor power supply)
container full
0V (low logic level/ power supply ground)
4
5
6
+Vin
eject confirm .
-V
-
Input
-
+V
N.O. contact*
ground
20-26Vcc, **
0V... +Vin
-
+V (high logic level/ sensor power supply)
ejection confirmation
0V (low logic level/ power supply ground)
7
8
9
+Vin
photocell
-V
-
Input
-
+V
N.O. contact*
ground
20-26Vcc, **
0V... +Vin
-
+V (high logic level/ sensor power supply)
photocell
0V (low logic level/ power supply ground)
10
11
12
+Vin
follow.conveyor
-V
-
Input
-
+V
N.O. contact
ground
20-26Vcc, **
0V... +Vin
-
+V (high logic level/ sensor power supply)
downstream belt authorisation
0V (low logic level/ power supply ground)
ALM-J11 - - - - -
reserved
ALM-J12 1
2
3
+Vin
Inhibition
-V
-
Input
-
+V
N.O. contact
ground
20-26Vcc, **
0V... +Vin
-
+V (high logic level)
inhibition
0V (low logic level)
4
5
6
+Vin
Reset
-V
-
Input
-
+V
N.O. contact
ground
20-26Vcc, **
0V... +Vin
-
+V (high logic level)
alarm reset
0V (low logic level)
7
8
9
10
+Vin
Encoder
-V
terra
-
Input
-
-
+V
N.O. contact
ground
ground
20-26Vcc, **
0V... +Vin
-
-
+V (high logic level/sensor power supply)
encoder impulses
0V (low logic level/ power supply ground)
ground
ALM-J14 - - - - -
reserved
ALM-J15 1
2
3
common
Cont. NC
Cont. NA
Output
Output
Output
common
N.C. contact
N.O. contact
250Vca 3A
250Vca 3A
250Vca 3A
auxiliary relay for test due notification
4
5
6
common
Cont. NC
Cont. NA
Output
Output
Output
common
N.C. contact
N.O. contact
250Vca 3A
250Vca 3A
250Vca 3A
authorisation upstream belt relay
ALM-J16 - - - - -
reserved
ALM-J17 1
3
4
L0
L1
PE
Input
Input
-
-
-
ground
230Vac ± 10% 48-62Hz
230Vac ± 10% 48-62Hz
-
mains power supply***
safety ground PE ****