THS – FI022GB2K8v3 --- V - MAINTENANCE
84
Maintenance
Any maintenance or repair of the device while open and energised should be avoided, and in any case should
only be carried out by trained personnel who are fully aware of the risks which the operation entails, following
the instructions given in the “Maintenance” section.
When the mains is disconnected using the main switch S1 of the Conveyor Control System, the power supply
section is deactivated, but the contacts which are connected permanently to the mains, e.g. the relay outputs,
remain energised.
N.B. When the I2 service switch is turned off, most components remain energised.
fig. V -1a fig. V -1b
Removal of the safety protections fitted to the device is strictly prohibited.
Periodic maintenance
Table V-1
Operation Period Operator
detection check
• beginning of each shift
• on changing product type
• periodically
• Quality-control operator
• Head of quality control
cleaning of conveyor belt beginning of each shift Operator
belt tension adjustment 6 months or when necessary maintenance personnel
locking of terminals used to connect
control panels
6 months maintenance personnel
Cleaning of barcode reader (if fitted)
with a non-abrasive cloth dampened
with alcohol
6 months or when necessary Operator
N.B.: clean when the device is
switched off
The operator must monitor the condition of the system and its suitability for use, and consult the maintenance
personnel if necessary.
S1
I2