EasyManua.ls Logo

Ceia THS - Counters Menu; Barcode Reader Menu

Ceia THS
106 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
THS – FI022GB2K8v3 --- V - MAINTENANCE
68
Counters menu
Remote Possible settings Standard setting Parameter
Cur. alar.
CA
0 – 999999999 -
Related to the current
product
Description Models
Number of alarms caused by the current product (since last reset)
To reset this counter select the parameter, press the key and press the (increase) key; in remote
programming execute the CR command.
All models
Remote Possible settings Standard setting Parameter
Cur. obj.
CO
0 – 999999999 -
Related to the current
product
Description Models
Number of transits of packs of current product (since last reset)
This count is performed through the photocell input.
To reset this counter select the parameter, press the
key and press the (increase) key; in remote
programming execute the CR command.
All models
Remote Possible settings Standard setting Parameter
Alar. cnt.
AC
0 – 999999999 -
Global
Description Models
Number of alarms (since last reset)
This counter increases with all products. To reset this counter select the parameter, press the key and press the
(increase) key; in remote programming execute the AR command.
All models
Remote Possible settings Standard setting Parameter
Obj. cnt.
OC
0 – 999999999 -
Global
Description Models
Number of packs (since last reset)
This count is performed through the photocell input.
This counter increases with all products. To reset this counter select the parameter, press the
key and press the
(increase) key; in remote programming execute the OR command.
All models
Barcode reader menu
This menu is available only with barcode reader fitted and BE parameter set to the right values.
Remote Possible settings Standard setting Parameter
Code
CD
See below -
Global
Description Models
Selection of type of coding
type of code recognised by the bar-code reader. Possible settings:
CODE 2/5 INTER, CODE 39 STAND, CODE 39 FULL, CODE 32, C.I.P., CODEBAR, CODE 128, EAN 128, CODE
93 STAND, EAN13, EAN8, UPCA, UPCE, EAN13 ADD ON 2, EAN8 ADD ON 2, UPCA ADD ON 2, UPCE ADD ON
2, EAN13 ADD ON 5, EAN8 ADD ON 5, UPCA ADD ON 5, UPCE ADD ON 5, PLESSEY, ALL EAN UPC
All models,
except THS/G
Remote Possible settings Standard setting Parameter
Code length
CL
1 – 48 / A A
Global
Description Models
Number of characters in the code
A
= Automatic
All models,
except THS/G
Remote Possible settings Standard setting Parameter
Decodes number
DN
1 - 10 -
Global
Description Models
Number of decodings with same result
Number of consecutive identical readings for a code to be considered valid.
All models,
except THS/G

Table of Contents