THS – FI022GB2K8v3 --- V - MAINTENANCE
58
Analysis mode selection criteria
The THS detector offers the possibility of choosing between three different types of detection, using the command
Analysis mode AM:
Selection criteria
Preferential applications
Analysis
mode AM
THS/M Other THS models
2
always
Distance between products at least 1.5 times the depth of
the tunnel (DL ).
3
not applicable
Distance between products can be less than 1.5 times the
depth of the tunnel (DL) with product characterised by a
TP setting (from autolearn procedure) in the range 200 to
1000.
4
not applicable
Reserved
5
not applicable
Reserved
6
not applicable
As analysis mode 2, with improved immunity
against vibrations
7
not applicable
As analysis mode 3, with improved immunity
against vibrations
In each case it is advisable to check operation with all types of detection, and to choose the one which provides
the highest level of sensitivity.