THS – FI022GB2K8v3 --- V - MAINTENANCE
79
Print report menu
Remote Possible settings Standard setting Parameter
Ejection report
JR
ON / OFF ON
Global
Description Models
Include Ejections in the personalized report
All models
Remote Possible settings Standard setting Parameter
Param. mod. rep.
MR
ON / OFF ON
Global
Description Models
Include Parameters modifications in the personalized report
All models
Remote Possible settings Standard setting Parameter
Test report
TR
ON / OFF ON
Global
Description Models
Include Quality Control Tests results in the personalized report
All models
Remote Possible settings Standard setting Parameter
Recent time
RT
00:00 – 23:59 1:00
Global
Description Models
Choose the time of the personalized report
Events printed on the Quality report (PR) are referred to this parameter. With RT = 2.00, for example, the printed
report refers to the last 2 hours of working.
All models
Remote Possible settings Standard setting Parameter
Print Report
PR
ON / OFF OFF
Global
Description Models
Print personalized report
The data are sent to the RS232
interface, if the command is
activated by local programming or
via RS232.
The data are sent to the RS485 if
the command is request via
RS485.
The printer report is filtered
according to JR, MR, TR and RT
parameters.
Example:
QUALITY REPORT 28/02/00 - 20:14:00
Serial number 999999
Line ID 1013
>Change product 28/02/00 - 20:13:13
P.Name P2
Operator ENGINEER
>Test Metal Detector 28/02/00 - 20:13:38
P.Name P2
Fe diameter 1.0
Test OK YES
Operator Q-C OPERATOR
>Test Metal Detector 28/02/00 - 20:13:49
P.Name P2
SS diameter 1.5
Test OK NO
Operator Q-C OPERATOR
>Statistics
END QUALITY REPORT
--------------------------------------------
All models