THS – FI022GB2K8v3 --- V - MAINTENANCE
80
Quality Control menu (Q.C.Report)
Remote Possible settings Standard setting Parameter
Print period
PP
00:00 – 23:59 00:00
Global
Description Models
Frequency of automatic printing of personalised report
If PP=00:00 the automatic printing
is disabled.
If PP>00:00, an automatic print of
the report is automatically sent to
the RS232. The printed report
includes the events selected with
JR, MR, TR, and a final statistic.
The interval which the data refers
to is related to the last automatic
print.
For example, setting PP=01.00,
each hour are printed the data
related to the last hour.
Example of personalized report:
QUALITY REPORT 28/02/00 - 20:13:00
Serial number 999999
Line ID 1013
>Change parameter 28/02/00 - 20:12:18
Sensitivity 202 -> 203
P.Name P2
Operator ENGINEER
>Ejection 28/02/00 - 20:12:31
P.Name P2
Ejection OK
>Ejection 28/02/00 - 20:12:44
P.Name P1
Ejection OK
>Change product 28/02/00 - 20:12:45
P.Name P1
Operator ENGINEER
>Ejection 28/02/00 - 20:12:49
P.Name P1
Ejection OK
>Statistics
P.Name P2
n. allarms 1
n. objects 8
Alarm rate 12.50 %
END QUALITY REPORT
-------------------------------------------
All models
Remote Possible settings Standard setting Parameter
Test period
TE
00:00 – 23:59 00:00
Global
Description Models
Pre-defined interval between Quality Control tests
If TE=00:00 the tests are disabled. If TE>00:00 a test is requested every TE interval.
All models
Remote Possible settings Standard setting Parameter
Test delay
TD
00:00 – TE 00:00
Global
Description Models
Waiting time for test to be carried out
Time within the operator should carry out test every TE interval.
Note: the need to carry out a test is signalled on the display.
All models
Remote Possible settings Standard setting Parameter
Fault time out
FT
ON / OFF ON
Global
Description Models
Activation of fault status if maximum time for test expires without performing the test
All models
Test Sensitivity menu (Test sensitiv.)
Remote Possible settings Standard setting Parameter
FE diameter
FD
0.0 – 25.0 -
Global
Description Models
Diameter of iron sample sphere used to perform the test
Datum that must be set for inclusion in the test report.
Note: The value is printed in the Q.C. report and does not effect the sensitivity.
All models