THS – FI022GB2K8v3 --- V - MAINTENANCE
77
Remote Possible settings Standard setting Parameter
Motor current
CU
0.000 – 5.000 A -
Global
Description Models
Nominal motor current
Set the nominal value for the motor connected to the MDL (this parameter is only significant on the version with MDL
card).
If the current drained to the motor is greater than CU, the belt stops and the “motor alarm” fault is given, both by the
display and
light. Usually CU must be set to the nominal current of the motor.
All models,
except THS/G
Remote Possible settings Standard setting Parameter
Max Inv. freq.
MI
60 – 100 -
Global
Description Models
Maximum inverter operating frequency
Sets the maximum nominal value of the motor operating frequency (this parameter is only significant on the version
with MDL card)
All models,
except THS/G
Remote Possible settings Standard setting Parameter
Lamp blinking
LB
ON / OFF OFF
Global
Description Models
Lamp flash option
OFF: when activated, the beacon connected to J22 pins 8 and 9, or the “test relay” are constantly activated.
ON: when activated, the beacon or the “test relay” are flashing (interval = 1s)
All models
I/O Status menu
Remote Possible settings Standard setting Parameter
-
-
H / L -
Global
Description Models
Display shows list of input and output lines with indication of their status
Example of display:
The inputs and outputs are shown on the display in real time.
FAULT relay H
EJECT relay L
ALARM relay L
PREC_CONV relay H
All models
MD Test menu
Remote Possible settings Standard setting Parameter
FE test
-
- -
Global
Description Models
Activation of the test for the standard iron reference sample
Test procedure: see “Periodic test management” section of the Instructions manual.
All models
Remote Possible settings Standard setting Parameter
SS test
-
- -
Global
Description Models
Activation of the test for the reference sample in stainless steel
Test procedure: see “Periodic test management” section of the Instructions manual.
All models,
except THS/MN
Remote Possible settings Standard setting Parameter
Non_FE test
-
- -
Global
Description Models
Activation of the test for the reference sample in diamagnetic metal
Test procedure: see “Periodic test management” section of the Instructions manual.
All models,
except THS/MN