148
No.
Error message on the
display
Possible cause Remedy
16 Unknown power class
An unknown or invalid power class
was detected. (valid are: 350A, 450A
or 600A)
Switch machine Off and On
Service
17
Weld blocking of
operating module
No enable from access
management.
Operating instructions
Service
18 Weld enable is missing
No enable available from the bus
system (VBC). No weld enable
available (is required for "External
start").
Weld enable
Check VBC
Service
19 Power enable is missing
Signal Arc enable from periphery is
missing. Power enable is missing. Is
required for each welding process
(see circuit diagram).
Check jumper, close if necessary
Service
20 Water shortage
Optional machine equipment.
Low water level.
Service
21 Low water flow rate
Optional machine equipment.
Water flow rate lower than limit
value (lines too long).
Option water monitoring, check water
flow rate
Check limit values
Refill coolant, if required.
Ventilate pump.
Check cooling circuit
Service
22 High water temperature
Optional machine equipment.
Water temperature higher than
limit value.
Option water monitoring, check water
temperature
Check limit values
Refill coolant, if required.
Ventilate pump
Service
23
Arc failure "Process
phase"
Arc interruption during the welding
process. During welding, the arc
parameters fall below a certain level
for more than 1 second.
Configuration menu C48
(ECO / Master)
Check process settings
Check wire drive unit
Check gas
Deactivate process monitoring
Service
24
Arc failure "Ignition
phase"
If the arc does not burn within 5
seconds after the start signal.
Configuration menu C49
(ECO / Master)
Check welding wire / wire drive unit
Service
25 Sense voltage exceeded
Optional machine equipment.
Voltage difference between Sense
voltage and terminal voltage
beyond preset limit value.
Check Sense voltage
Check earth connection
Check threshold value Configuration
menu C55
Service

Table of Contents