MAIN (2) - Config (Configuration)
10.4 Config - Water monitoring
The water monitoring is inactive if no sensors are available or the pump is
switched off, see chapter 10.1.3 on page 73.
Use the arrow symbols to switch between the individual menu items.
Water flow rate
In the menu "Water monitoring" the minimum water flow rate can be
monitored.
• The limit value is set in l/min. The limit value should not fall below
1.2 l/min.
• The start delay allows a trouble-free recording of the measured values.
In addition, an error must exist for a certain error time in order to be
detected as error.
• If "Message" has been selected, an output signal exists on the CAN bus
of the welding power source. This signal can be processed by a periph-
eral control (PLC). If "Abort" is selected, the Arc start command will be
reset in the event of an error.
Water temperature
In the "Water temperature" menu, the temperature of the coolant can be
monitored.
• The limit value is set in °C. The limit value should not exceed 60°C.
• The start delay allows a trouble-free recording of the measured values.
In addition, an error must exist for a certain error time in order to be
detected as error.
• If "Message" has been selected, an output signal exists on the CAN bus
of the welding power source. This signal can be processed by a periph-
eral control (PLC). If "Abort" is selected, the Arc start command will be
reset in the event of an error.
ATTENTION!
Puls 4 -Takt
V
0
A
1.2 mm Fe
82% Argon 18% Co
2
0.0
Konfig -Wasseberwachung
Wasserüberwachung
Schwellwert (l/min) 1.0
Verzögerung (sek.) 1.0
Fehlerzeit (sek.) 1.0
Überwachung Abbruch
Wassertemperatur
Schwellwert (ºC) 1.0
Verzögerung (sek.) 1.0
Fehlerzeit (sek.) 1.0
Überwachung Melden
Puls 4 -Takt
V
0
A
1.2 mm Fe
82% Argon 18% Co
2
0.0
Puls 4 -Takt
V
0
A
1.2 mm Fe
82% Argon 18% Co
2
0.0
Konfig -Wasserüberwachung
Wasserüberwachung
Schwellwert (l/min) 1.0
Verzögerung (sek.) 1.0
Fehlerzeit (sek.) 1.0
Überwachung Abbruch
Wassertemperatur
Schwellwert (ºC) 1.0
Verzögerung (sek.) 1.0
Fehlerzeit (sek.) 1.0
Überwachung Melden