MAIN (2) - Config (Configuration)
10.9 Config - Process monitoring
Arc existing process control
If the signal "Arc existing" is not active for more than 1 second during the
welding process (process phase), the error message "Err. 23 Arc failure pro-
cess phase" will appear on the display.
You have the following options:
• Off
• Reset on Start
The error message is reset at the next "Welding start" signal.
• Reset from external
The error message is reset by an external signal (OMI or bus system).
Ignition control
If there is no signal "Arc existing" within 5 seconds after the command
"Start welding", the error message "Err. 24 Arc failure ignition phase" will
appear on the display.
You have the following options:
• Off
When the ignition control is off, wire feed will continue in case of a trouble
signal.
• Reset on Start
The error message is reset at the next "Welding start" signal.
• Reset from external
The error message is reset by an external signal (OMI or bus system).
ATTENTION!
Puls 4 -Takt
V
0
A
1.2 mm Fe
82% Argon 18% Co
2
0.0
Konfig Prozessüberwachung
LB-Steht Prozesskontrolle
Reset bei Start
Funktion
ndkontrolle
Reset bei Start
Funktion
Puls 4 -Takt
V
0
A
1.2 mm Fe
82% Argon 18% Co
2
0.0
Puls 4 -Takt
V
0
A
1.2 mm Fe
82% Argon 18% Co
2
0.0
Konfig Prozessüberwachung
LB-Steht Prozesskontrolle
Reset bei Start
Funktion
ndkontrolle
Reset bei Start
Funktion
Figure 50. Process monitoring