66
MAIN - Progr. (Programming)
7.7.3 "DuoPulse parameters" in the "Expert Mode"
DuoPulse is not an independent pulsed arc welding process but only a
changing between two parameter settings.
If the "Expert Mode" function is active, the "DuoPulse parameters" function
is available for the start, main and end program in the "PROGRAMMING"
menu.
DuoPulse
On Off
DP mode
Energy Wire/Energ Wire
In the position "Energy"
the 2nd parameter set
is generated by the
parameters which can
be selected in the dis-
play (depending on the
process).
In the position "Wire/en-
erg" the 2nd parameter
set is generated from all
2nd parameters which
are shown in the display.
In the position "Wire"
the 2nd parameter
set is generated only
by modifying the wire
speed.
DP frequency:
The selected frequency is used to switch between the selected original
parameters and a 2nd parameter set so that an almost pulsating arc is
produced.
INFO!
Startmenü
Expert Mode
DuoPuls H A U P T
Puls 2 -Takt
V
0
A
1.2 mm Fe
82% Argon 18% CO
2
0.0
DP-Frequenz 1.5 Hz
DP-Tastverhältnis 50 %
2. Pulszeit 1.9 ms
2.Pulsstrom 450 A
2. Grundstrom 60 A
Duopuls Ein
DP-Modus Draht/Energ
2. Drahtvorschub 11. m/min
Startmenü
Expert Mode
DuoPuls H A U P T
Puls 2 -Takt
V
0
A
1.2 mm Fe
82% Argon 18% CO
2
0.0
DP-Frequenz 1.5 Hz
DP-Tastverhältnis 50 %
2. Pulszeit 1.9 ms
2.Pulsstrom 450 A
2. Grundstrom 60 A
Duopuls Ein
DP-Modus Draht/Energ
2. Drahtvorschub 11. m/min
Figure 23. "DuoPulse parameters" for "Vari Weld" process