Introduction Engineering Manual
14
Mains Wiring
All mains wiring must be carried out only by a qualified electrician and must comply with
current local regulations.
Data
Network
CONTROL
PANEL
100 metres 100 metres
100 metres 100 metres 100 metres
1 km (Max.)
Out
In
XNode/
MNode
XNode/
MNode
Node/
MNode
Node/
MNode
Node/
MNode
XNode/
MNode
XNode/
MNode
XNode/
MNode
I/D=1 I/D=3 I/D=6 I/D=7 I/D=8
I/D=5
I/D=2 I/D=4
OutIn OutIn OutIn OutIn
Node/
MNode
Node/
MNode
I/D=10I/D=9
Out
In
Out
In
Node/
MNode
I/D=11
OutIn
Out
Out
Out
In
In
In
100 metres
4-Core
4-Core
100 metres
100 metres 100 metres
1 km (Max.)
Daisy-chained Connections
Star and Daisy-chained Connections
NOTE:
The maximum number of devices
that can be "Star" connected from
the output of the XNode, MNode or
control panel is 4.
XNodes/
MNodes
5 to 16
OutIn
XNode/
MNode
XNode/
MNode
Node/
MNode
Node/
MNode
Node/
MNode
I/D=1 I/D=2 I/D=3 I/D=4 I/D=16
Out
In
Out
In
Out
In
Out
In
Data
Network
CONTROL
PANEL
Figure 4. Maximum Distances to XNodes or MNodes
100m max
CONTROL
PANEL
Keypads
100m max
CONTROL
PANEL
Keypads/LEC2s
100m max
XNode/
MNode
Figure 5. Maximum Distances to Keypads/LEC2s