EasyManua.ls Logo

Cooper Security M750 - Ward Events

Cooper Security M750
140 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Engineering Manual Engineer Menu 1-4
51
131 – Time Switch 3 On
Activates while time switch 3 (page 62) is active.
132 to 138 – Always Off
This output never activates.
139 – Code Lock 1 On
Activates when “Code lock timer 1" is on; deactivates when the timer is off (see page
64).
140 – Code Lock 2 On
Activates when “Code lock timer 2" is on; deactivates when the timer is off (see page
64).
141 – Code Lock 3 On
Activates when “Code lock timer 3" is on; deactivates when the timer is off (see page
64).
142 to 148 – Always Off
This output never activates.
Ward Events
The following events are applicable if you have chosen the output to follow a specific ward:
00 – Bell-SAB
Activates when the selected ward is in alarm and the control panel bell output is on, and
deactivates when the bell output is off. The bell output may be activated on a confirmed
or unconfirmed alarm, depending on whether Bells on Confirm or Bells on Unconf is
selected (page 77).
01 – Strobe
Activates when the selected ward is in alarm and the control panel strobe output is on;
deactivates when the selected ward is reset.
02 – Switch 12
Activates when the selected ward is set; deactivates when the selected ward is in alarm,
its Entry Delay timer (page 57) is running or the ward is unset. This output is normally used
as an input to latching detectors.
03 – Det. Reset
Deactivates for approximately 4 seconds when a user code is entered to set the first
ward. The output is used to reset latching detectors (smoke detectors, shock sensors,
etc.).
04 – Walk Test
Activates when the selected ward is walk tested (User option 1-1-2); deactivates when the
walk test is exited.
05 – Alarm
Activates when the selected ward has a full alarm (page 26); deactivates when the
alarm has been reset.

Table of Contents