Engineering Manual Engineer Menu 1-9
81
Engineer
– An alert generated by a mains failure will require an engineer or remote reset.
11 – AC Bypass:Always / User / Eng
Always
(default)
– With this option selected, an AC Mains Fault alert will not prevent a user
from being able to set the alarm system.
Healthy – Allows a user to override an AC fail alert and set the system, but only if mains is
present.
Never – Prevents the alarm system from being set if there is an AC fail alert that needs to
be reset. If the AC Fail option is set to Engineer, the system will be able to be set only
after the alert is reset by an engineer or remote reset.
12 – Line Fail:No Rst / User / Eng
No Rst
(default)
– A line fault (e.g. no dial tone present) detected by the on-board
modem (not available for M550 and M750 systems) or by an external communicator will
cause an alert to be generated, but the alert will disappear when the line is restored. No
resetting of the alert will be required.
The on-board modem can generate a "PSTN Line Fault" only if communications from the
on-board modem to an Alarm Receiving Centre (ARC) has been enabled (see page
91).
An external communicator must connect to the LINE FLT input of the panel to signal a
line fault. The line fault alert is "ATE L.F. Single" or "ATE L.F. All" (see page 48).
User
– An alert generated by a line fault will require a normal user reset.
Engineer
– An alert generated by a line fault will require an engineer or remote reset.
13 – LF Bypass:Always / User / Eng
Always (default) – With this option selected, an PSTN Line Fault alert will not prevent a user
from being able to set the alarm system.
User – Allows a user to override an PSTN Line Fault alert and set the system, but only if
there is no line fault.
Eng – Prevents the alarm system from being set if there is a PSTN Line Fault alert that
needs to be reset. If the Line Fail option is set to Eng, the system will be able to be set
only after the alert is reset by an engineer or remote reset.
Option 1-0: Going to User Menu 1
This option allows you to access User menu 1. For details of the options in this menu, please
refer to the Manager's Manual.
You can use user option 1-4 to change the engineer code.