Engineering Manual Engineer Menu 1-4
55
40 – Auto set
Activates when the selected Secure ward (page 37) is unset; deactivates when the
Secure ward is set.
Zone Events
The following events are applicable if you have chosen the output to follow a specific zone:
1 – Mimic
Activates when the selected zone is active; deactivates when the selected zone is not
active. The output can follow any zone, including those that are "Not used".
Depending on whether Mimic, All Times or Mimic Set Only is selected (page 76), the
output may mimic the zone only if the zone is in a set ward.
2 – Alarm
Activates when the selected zone causes a full, local or internal alarm (page 26);
deactivates when the alarm has been reset.
3 – Tamper
Activates when the selected zone is in tamper (irrespective of whether the zone's ward is
set); deactivates when tamper is reset.
4 – Test Fail
Activates when the selected zone is triggered while on soak test (page 30); deactivates
when the engineer enters the engineer code.
5 – Omit
Activates when the selected zone is omitted or shunted (User option 1-2 or 1-3);
deactivates when the selected zone has the omit/shunt removed.
Step 6 – Select the Inversion and Output Mode
Output Inversion
Selecting this option inverts the sense of the output.
Output Mode
Output Mode is not available for certain outputs types.
The normal mode is Latched.
Selecting Pulsed causes the output always to return to its normal state after the specified
number of seconds. This can result in the output returning to the normal state sooner than if the
Latched mode is selected.