Engineer Menu 1-4 Engineering Manual
54
To use this feature, assign the Sndr Ctl output type to the output of the relevant keypad
and fit the jumper across the "WARD SNDR" link in the keypad (see the Keypad Installation
Instructions). Assign the XNode/MNode/loudspeaker to all used wards. The keypad
sounder will operate only when the output is switched on, i.e. when a sound is required
for the specified ward.
29 – Perimeter
Activates when the selected ward has a Perimeter zone (page 28) in alarm; deactivates
when the alarm is reset.
30 – Shunted
Activates when the selected ward has one or more zone shunted (by User option 1-3);
deactivates when the zones are reinstated.
31 – AlwaysOff
Never activates.
32 – SetStrobe
Activates when there is an alarm in the selected ward, and deactivates when a user
resets the alarm. The control panel also activates this output for 10 seconds after a user
sets the ward.
33 – Access
If the Access Code Only configuration option is set (page 75), this output activates when
a user code of type Access assigned to the selected ward is entered. If the Access All
Codes option is set (page 75), this output activates when any valid user code assigned
to the selected ward is entered. The output deactivates one second later if the output is
latched, or for the length of the pulse if the output is pulsed.
34 – LS Open
Active when a Lock Set zone (page 28) in the selected ward is unlocked.
35 – PSU Batt
Activates while a PSU Battery zone (page 29) in the selected ward is active.
36 – PSU Fuse
Activates while a PSU Fuse zone (page 29) in the selected ward is active.
37 – PSU Mains
Activates while a PSU Power zone (page 29) in the selected ward is active.
38 – Mask Tamp
This is applicable only if the Mask Unset Tamp or Mask Set Tamper option is selected
(page 80). The output activates when a masking condition has been detected in the
selected ward (see page 29). The Anti Mask timer (page 59) delays activation of the
output.
39 – Mask Flt
This is applicable only if the Mask Unset Fault or Mask Set Fault option is selected (page
80). The output activates when a masking condition has been detected in the selected
ward (see page 29). The Anti Mask timer (page 59) delays activation of the output.